Questions? Let us help:
1.877.766.5412

Contact Us

AEMC F07 Clamp-on Meter

Model: F07

AEMC F07 Clamp-on Meter (TRMS, 400AAC/DC, 600VAC/DC, Hz, Ohms, Continuity, Temperature)

Sorry! This product has been discontinued.


The AEMC F07 Clamp-on Meter has been discontinued, it has been replaced by the AEMC 407 Clamp-on Meter




The AEMC F07 is a high performance clamp-on meter built into a rugged compact sized case, with exceptional ergonomic design and extraordinary measurement possibilities.
Integrating a fast microprocessor sampling at a high rate, the Model F07 is completely automatic and performs TRMS measurements on the most distorted waveforms. The Model F07 measures TRMS Voltage and Current and can incorporate the DC component of the signal for the Truest RMS. It has a V-LiveĀ™ function to warn of the use of live circuits or elevated voltages.Temperature measurements up to 1832°F (1000°C) can be taken via standard K thermocouple. The Model F07 can measure in-rush currents from 1 cycle up to 10 cycles and frequency. Other features include: auto-ranging, 4000-count display and Auto-Off.
Electrical
Measurement Range 40V: 0.2 to 39.99V / 400V: 40.0 to 399.9V / 4000V: 400 to 600V (400 to 900V pk)
Accuracy 40V: 1% of reading + 5cts / 400V: 1% of reading + 2cts / 4000V: 1% of reading + 2cts
Continuity
Measurement Range 0.0 to 399.9Ω;
Accuracy 1% of reading + 2cts
Resistance
Measurement Range 400Ω: 0.0 to 399.9Ω / 4000Ω: 400 to 3999Ω / 40000Ω: 4.0 to 39.99kΩ;
Accuracy 1% of reading + 2cts
Diode
Measurement Range 4V: 0 to 3.199V
Current
Measurement Range 40A: 0.20 to 39.99A / 400A: 40 to 399.9A / 4000A: 400 to 600A pk
Accuracy 40A: 1.5% of reading + 10cts / 400A: 1.5% of reading + 2cts / 4000A: 1.5% of reading + 2cts
Resolution 40A: 10mA / 400A: 100mA / 4000A: 1A
Inrush Function
Range for use ≥5A pk for the first period of the signal
Accuracy 5% + 0.5A
Capture Time 0.5 to 10 periods of the signal frequency (8 to 160ms at 60Hz)
Frequency
Measurement Range 40Hz: 10.00 to 39.99Hz / 400Hz: 40.0 to 399.9Hz / 4000Hz: 400 to 3999Hz / 40000Hz: 4.00 to 19.99kHz
Accuracy 40Hz - 40kHz: 0.4% of reading + 1ct
General
Display 4 digits, 9999 counts, 3 decimal points, "+" & "-" signs (DC and peak measurement)
Operating Temperature 32° to 122°F (0° to 50°C); 90% RH
Storage Temperature 40° to 158°F (-40° to 70°C); 90% RH
Power Source 9V Alkaline Battery (type IEC 6LF22, 6LR61, or NEDA 1604)
Jaw Opening ≤1.00" (≤26mm)
Dimensions 2.76 x 7.6 x 1.46" (70 x 193 x 37mm)
Weight 9.17 oz (260g)
Safety
Safety Rating EN62020-1, EN61010-2-032, 600V CAT III
CE Mark Yes

Current Promos

Get Free Shipping on any purchase over $299


NULL