Questions? Let us help:
1.877.766.5412

Contact Us

AEMC 670 Clamp-on Meter

Model: 670

AEMC 670 Clamp-on Meter (Dual Display, TRMS, AC Amps, AC/DC Volts, Ohms, Continuity, Frequency, & Temperature)

$229.00 USD

Checking inventory...




The AEMC 670 Clamp-on Meter is a general purpose professional clamp-on meter that measures up to the toughest standards. This meter offers a complete set of measurement ranges (AC Amps, DC Amps, AC Volts, DC Volts, Ohms, Continuity with beeper, Frequency from V or A, and Temperature) and is in compliance with international safety and quality standards to ensure professional and reliable measuring tools.

This meter is designed to measure and display amps and volts at the same time. It also is auto-ranging and provides the best measurement range and resolution for troubleshooting.

The AEMC 670 Clamp-on Meter is sized for comfortable, one-handed operation. The tapered and hooked jaw design facilitates maneuvering in crowded wiring and breaker panels, making it easy to select conductors. The jaw opening accommodates one 750kcmil cable or two 350kcmil cables. The large and easy-to-read 9999-count LCD features comprehensive user information symbols, such as low battery, polarity, overload, and an analog bargraph for easy trend readings.

The AEMC 670 Clamp-on Meter is equipped with a Data Hold function that freezes the measurement for later viewing, Min/Max, and Peak function for capture of signals. This AEMC 670 Clamp-on Meter is a True RMS clamp-on meter that provides RMS measurements for today's non-linear electrical environments.


Applications

  • Commercial, industrial, residential and HVAC troubleshooting
  • Power panel, junction box and battery bank monitoring
  • AC or DC motor testing
  • Power plant troubleshooting
  • Electrical testing and troubleshooting on non-linear loads, such as adjustable speed drives and computers

Key Features

  • Standard size, full function clamp-on meter
  • 1000AAC current measurements
  • 1400VDC volt measurements
  • TRMS measurements
  • Resistance measurement to 10,000Ω
  • Continuity with beeper below 35Ω
  • Frequency measurements from V and A
  • 1ms Peak function for fast capture of signals
  • Hold function to "freeze" readings
  • Designed to measure Amps and Volts at the same time
  • Push-button for easy ADC zeroing
  • Large easy-to-read 9999-count backlit display
  • Includes test leads and soft carrying case

Specifications

MODEL 670 675
ELECTRICAL
AC AMPERES
Range 100A 1000A 100A 1000A
Measuring Range 0.0 to 999.9V 1000 to 1400V 0.0 to 999.9V 1000 to 1400V
Resolution 0.1V 1V 0.1V 1V
Accuracy 1% ± 2cts 1% ± 2cts
Input Resistance 1MΩ 1MΩ
Overload 1400Vdc 1400Vdc
RESISTANCE-OHMS (Ω)
Range 1000Ω 1000Ω 1000Ω 1000Ω
Measuring Range 0.0 to 999.9O 1000 to 9999Ω 0.0 to 999.9Ω 1000 to 9999Ω
Resolution 0.1Ω 0.1Ω 0.1Ω
Accuracy 1% ± 3cts, 3.3Vdc (Vmax) 1% ± 3cts, 3.3Vdc (Vmax)
Protection 1000Vrms 1000Vrms
Continuity
Range Yes Yes
Beeper Activation <35Ω <35Ω
Accuracy 1% ± 3cts, 3.3Vdc (Vmax) 1% ± 3cts, 3.3Vdc (Vmax)
Protection 1000Vrms 1000Vrms
Frequency (Hz)
Function A - Hz V - Hz A - Hz V - Hz
Range 1000Hz 10,000Hz 1000Hz 10,000Hz
Resolution 0.1Hz 1Hz 0.1Hz 1Hz
Sensitivity 3Arms 5Vrms 3Arms 5Vrms
Accuracy 1.0% ± 2cts 1.0% ± 2cts
Temperature ( °C / °F )
Range 1000°C 1200°C 2192°F 1000°C 1200°C 2192°F
Measuring Range -40 to 999.5°C 1000 to 1200°C -40 to 2192°F -40 to 999.5°C 1000 to 1200°C -40 to 2192°F
Resolution 0.5°C 1°C 1°F 0.5°C 1°C 1°F
Accuracy 1.0% ± 2°C 1.0% ± 2°C 1.0% ± 4°C 1.0% ± 2°C 1.0% ± 2°C 1.0% ± 4°C
GENERAL
Low Battery Indicator Yes Yes
Power Supply 9V, NEDA 1604 (6F22) alkaline 9V, NEDA 1604 (6F22) alkaline
Battery Life (no buzzer or backlight) 35 hours (no buzzer or backlight) 30 hours
Polarity Yes Yes
MECHANICAL
Digital Display 3 ¾ digits LCD dual display (max reading 9999) 3 ¾ digits LCD dual display (max reading 9999)
Jaw Opening 1.57" (40mm) 1.65" (42mm)
Dimension 10.71 x 3.15 x 1.69" (272 x 80 x 43mm) 10.12 x 3.15 x 1.69" (257 x 80 x 43mm)
Weight 17 oz (480g) with battery 15.5 oz (440g) with battery
Protection Index Of Housing IP30 according to EN 60529 Ed. 92 IP30 according to EN 60529 Ed. 92
ENVIRONMENTAL
Altitude 2000 meters 2000 meters
Operating Temperature 32° to 104°F (0° to 40°C) < 70% RH 32° to 104°F (0° to 40°C) < 70% RH
Storage Temperature 14° to 140°F (-10° to 60°C) < 80% RH 14° to 140°F (-10° to 60°C) < 80% RH
Pollution Degree 2 2
SAFETY
Safety Rating EN 61010-1 Ed.2001; EN 61010-2-032 Ed.2002 600V Cat. IV, 1000V Cat. III EN 61010-1 Ed.2001; EN 61010-2-032 Ed.2002 600V Cat. IV, 1000V Cat. III
CE Mark Yes Yes