AEMC 514 Digital Clamp Meter

Model: 514

AEMC 514 Digital Clamp Meter (AC/DC, TRMS, 1000AAC/DC, 750VAC/1000VDC, Ohms, Continuity)

$199.00 USD

Ships in 7 Days

Add In House NIST Traceable Calibration to your AEMC 514 Digital Clamp Meter

Clear selected options






The AEMC 514 Clamp Meter is a general purpose professional clamp-on meter that measures up to the toughest standards. It is built into a rugged mechanical case and is designed using quality polycarbonate materials. This meter offers a complete set of measurement ranges and is in compliance with international safety and quality standards to ensure a professional and reliable measuring tool. The AEMC 514 is auto-ranging and provides the best measurement range and resolution for troubleshooting. It has a high resolution 40A range.

AEMC 514 measures AC Amps, AC Volts, DC Volts, Ohms, Continuity (with beeper), Frequency (from V or A) and has a Diode Test function. It also uses Hall sensor technology that provides both DC and AC current measurements to 1000A.

The AEMC 514 is sized for a comfortable, one-handed operation. This model is TRMS and designed for today's non-linear loads. The jaw opening for the Model 514 is 1.575" (40mm).

Applications

  • Commercial, industrial, residential and HVAC troubleshooting
  • Power panel, junction box and battery bank monitoring
  • AC or DC motor testing
  • Power plant troubleshooting
  • Electrical testing and troubleshooting on non-linear loads, such as adjustable speed drives and computers

What's Included

  • Pair of Test Leads
  • 9V Battery
  • Soft Carrying Case
  • User Manual

Key Features

  • Standard size, full function clamp-on meter
  • 1000AAC/DC current measurements
  • 750VAC/1000VDC volt measurements
  • TRMS measurements
  • Resistance measurement to 4000Ω
  • Continuity with beeper below 40Ω
  • Frequency measurements from V and A
  • Diode test
  • 1ms Peak function for fast capture of signals
  • Hold function to "freeze" readings
  • Push-button for easy ADC zeroing
  • Large easy-to-read 4000-count display
  • 42-segment analog bar-graph
  • Includes test leads and soft carrying case

Specifications

AC Current
Range 0.05A to 1000A
Resolution 40A: 0.01A; 400A: 0.1A; 1000A: 1A
Basic Accuracy 50 to 60Hz: ±1.9% of Reading + 5cts; 60 to 500Hz: ±2.5% of Reading + 5cts
Frequency Range 50 to 500Hz
Overload Protection 40A: 1200Arms; 400A: 1200Arms; 1000A: 1200Arms
DC Amperes
Range 1A to 1000A
Resolution 40A: 0.01A, 400A: 0.1A; 1000A: 1A
Accuracy ±2.5% of Reading + 10cts
Overload Protection 1200Arms
AC Volts
Input Range 0.5V to 750V
Range 400V / 750V
Resolution 0.1V / 1V
Accuracy ±1.5% of Reading + 5cts
Input Impedance 10MW
Overload Protection 1000Vrms
Frequency Current Input
Range 4kHz
Resolution 1Hz
Minimum Input Signal 2Arms
Accuracy ±0.1% of Reading + 1ct
Frequency Voltage Input
Range 10kHz
Resolution 10Hz
Minimum Input Signal 5Vrms
Accuracy ±0.1% of Reading + 1ct
DC Volts
Range 0.2 to 1000V
Resolution 400V: 0.1V; 1000V: 1V
Accuracy ±1% of Reading + 2cts
Input Impedance 10MW
Overload Protection 1200Vrms
Continuity
Range Beeper
Measurement <40W
Max. Test Voltage 3VDC
Overload Protection 600Vrms
General Specifications
Digital Display Digital: 3¾ digits LCD display, 4000 count (max. reading 3999)
Analog Display Fast 42-segment analog bargraph display
Symbol & Scale Range Automatic according to range and input signal
Polarity Minus sign displayed when negative signal applied to input
Overload OL Displayed when input signal exceeds range
Sample Rate 2 samples/sec for the digital display; 20 samples/sec for the analog bargraph
Jaw Opening Size 1.575" (40mm)
Battery 9V, NEDA 1604 or 6F22 or 006P
Low Battery Indicator Symbol displayed when the battery is below the required voltage
Auto Power Off The meter will power itself OFF if there is no push button or rotary switch operation for 30 minutes
Dimensions 9.53 x 2.60 x 1.42" (242 x 66 x 36mm)
Weight 14.10oz (400g) with batteries
Environmental Specification
Operating Temperature 32° to 104°F (0° to 40°C), <80% RH, non-condensing
Storage Temperature 14° to 140°F (-10° to 60°C), <70% RH, battery removed
Operating Altitude 2167 ft (2000m)
Safety / Reference Specifications Safety / Reference Specifications
Protection Level Double insulation; EN 61010, 600V, Cat. III and EN 61010, 1000V, Cat. II
Agency Approvals CE Mark